Surge Arrester – Type 1+Type 2

FLP7-275/1S+1+Spare module (OBO)

Modular surge arrester for use in single-phase TT and TN systems (“1+1” circuit); with floating remote signalling contact.

  • Prewired complete unit consisting of a base part and plug-in protection modules
  • High discharge capacity due to heavy duty zinc oxide varistors / spark gaps
  • High reliability due to “Thermo Dynamic Control” SPD monitoring device
Surge-protective-device-FLP7-275-1S+1+Spare-Module-OBO
Dimensions-FLP7-275-1S+1+Spare-Module-OBO-style
Dimensions
Basic-circuit-diagram-FLP7-275-1S+1+Spare-Module-OBO-style
Basic circuit diagram

Technical data

TypeFLP7-275/1S+1+Spare module
SPD according to EN 61643-11 / IEC 61643-11type 1 + type 2 / class I + II
Nominal a.c. voltage Un275 V AC (48/62 Hz)
Max. continuous operating a.c. voltage [L-N] Uc320 V AC (48/62 Hz)
Max. continuous operating a.c. voltage [N-PE] Uc255 V AC (48/62 Hz)
Nominal discharge current (8/20μs) In20 kA
Maximum discharge current (8/20μs) Imax50 kA
Lightning impulse current (10/350μs) [L-N] Iimp7 kA
Lightning impulse current (10/350μs) [N-PE] Iimp25 kA
Voltage Protection level [L-N] Up1,6 kV
Voltage Protection level [N-PE]  Up1,5 kV
Follow current extinguishing capability [N-PE] Ifi100 Arms
Response time [L-N] tA25 ns
Response time [N-PE] tA100 ns
Max. mains-side over-current protection160 A gL/gG
Short-circuit current rating ISCCR50 kA
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic335 V / 5 sec. – withstand
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic440 V / 120 min. – safe failure
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic1200 V / 200 ms – withstand
Range of operating temperatures (TU)-40/+80°C
Operating state / fault indicationgreen / red
Number of ports1
Cross-sectional area (min.)1.5 mm2 solid /flexible
Cross-sectional area (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rail acc. to EN 60715
Enclosure materialthermoplastic
Place of installationindoor installation
Degree of protectionIP 20
Capacity3 module(s), DIN 43880
ApprovalsCE
Type of remote signalling contactchangeover contact
a.c. switching capacity250V / 0.5 A
d.c. switching capacity250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible

Downloads:

Other products in this category 


Surge-arrester-FLP7-275-1-OBO

FLP7-275/1 (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

1P

Surge-arrester-FLP7-275-1S+1-OBO

FLP7-275/1S+1 (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

1+NPE, single-phase, for TT and TN systems

Surge-arrester-FLP7-275-2S-OBO

FLP7-275/2S (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

2P, single-phase, for TN systems

Surge-arrester-FLP7-275-2S+1-OBO

FLP7-275/2S+1 (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

2+NPE, three-phase, for TT and TN-S systems

Surge-arrester-FLP7-275-3S-OBO

FLP7-275/3S (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

3P, three-phase, for TN-S systems

Surge-arrester-FLP7-275-3S+1-OBO

FLP7-275/3S+1 (OBO)

Un = 275 Vac

Iimp (10/350μs) = 7 kA

3+NPE, three-phase, for TT and TN-S systems