TypeSLP40K-275/2SLP40K-275/2S
SPD according to EN 61643-11 / IEC 61643-11type 2 / class IItype 2 / class II
Nominal a.c. voltage UN275 V AC (48/62 Hz)275 V AC (48/62 Hz)
Max. continuous operating a.c. voltage UC320 V AC (48/62 Hz)320 V AC (48/62 Hz)
Nominal discharge current (8/20μs) In20 kA20 kA
Maximum discharge current (8/20μs) Imax40 kA40 kA
Voltage Protection level UP1,6 kV1,6 kV
Response time tA25 ns25 ns
Max. mains-side over-current protection125 A gL/gG125 A gL/gG
Short-circuit current rating ISCCR25 kArms25 kArms
Temporary overvoltage (TOV) (UT) – Characteristic335 V / 5 sec. – withstand335 V / 5 sec. – withstand
Temporary overvoltage (TOV) (UT) – Characteristic440 V / 120 min. – safe failure440 V / 120 min. – safe failure
Range of operating temperatures (TU)-40/+80°C-40/+80°C
Operating state / fault indicationgreen / redgreen / red
Number of ports11
Cross-sectional area (min.)1.5 mm2 solid /flexible1.5 mm2 solid /flexible
Cross-sectional area (max.)35 mm2 stranded / 25 mm2 flexible35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rail acc. to EN 6071535 mm DIN rail acc. to EN 60715
Enclosure materialthermoplasticthermoplastic
Place of installationindoor installationindoor installation
Degree of protectionIP 20IP 20
Capacity1 module(s), DIN 438801 module(s), DIN 43880
Approvals
Type of remote signalling contactchangeover contact
a.c. switching capacity250V / 0.5 A
d.c. switching capacity250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible

Downloads:

Other products in this category 


surge-protector-slp40k-275-1s1

SLP40K-275/1S+1

Un = 275 Vac

Imax (8/20μs) = 40 kA

1+NPE, single-phase, for TT and TN systems

surge-protector-slp40k-275-3s1

SLP40K-275/3S+1

Un = 275 Vac

Imax (8/20μs) = 40 kA

3+NPE, three-phase, for TT and TN-S systems

surge-protector-slp40k-275-4s

SLP40K-275/4S

Un = 275 Vac

Imax (8/20μs) = 40 kA

4P, three-phase, for TT and TN-S systems