Disassembling DEHNvapDVA CSP 3P 100 S FM, Part no. 900 367


DEHNvap DVA CSP 3P 100 S FM pic1

DEHNvap DVA CSP 3P 100 S FM pic2

DEHNvap DVA CSP 3P 100 S FM pic3

  • Prewired combined lightning current and surge arrester, energy-coordinated with power supply systems for cell sites (DEHNvap CSP … CellSite Protection)
  • Encapsulated spark gap technology with a width of only 1 module/pole allows compact and space-saving design for easy installation within the power supply cabinets
  • Combined lightning current and surge arrester for use in triphase TT and TN systems (3+1 configuration) for protecting 230 V power supply systems of cell sites

DEHNvap DVA CSP 3P 100 S FM

Basic circuit diagram DVA CSP 3P 100 S FM

Dimension drawing DVA CSP 3P 100 S FM

Technical data

SPD according to EN 61643-11 / … IEC 61643-11type 1 + type 2 / class I + class II
Energy coordination with terminal equipment (≤ 10 m)type 1 + type 2 + type 3
Nominal voltage (a.c.) (UN)230 / 400 V (50 / 60 Hz)
Max. continuous operating voltage (a.c.)[L-N]/[N-PE] (UC)255 V (50 / 60 Hz)
Lightning impulse current (10/350 μs) [L-N]/[N-PE] (Iimp)25 / 100 kA
Specific energy [L-N]/[N-PE] (W/R)156.25 kJ/ohms / 2.50 MJ/ohms
Nominal discharge current (8/20 μs) (In)25 / 100 kA
Voltage protection level [L-N] / [N-PE] (UP)≤ 1.5 kV / ≤ 1.5 kV
Follow current extinguishing capability [L-N]/[N-PE] (Ifi)25 kArms / 100 Arms
Follow current limitation/Selectivityno tripping of a 32 A gGfuse up to 25 kArms (prosp.)Response time
Response time [L-N] (tA)≤ 100 ns
Max. backup fuse (L) up to IK> 25 kArms250 A gG
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic440 V / 120 min. – withstand
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic1200 V / 200 ms – withstand
Additional abnormal voltage test: 485 V AC / 50 Hz for 24 hwithstand
Let-Through-Energy in combination with an MOV S20K275 (Iimp =2.5 … 25 kA)< 0.5 J
Safe behavior at U = 320 V and ISCCR = 13.5 kA in combination with a fuse 63 A gGwithstand
Operating temperature range [parallel]/[series] (TU)-40°C…+80°C
Operating state/fault indicationgreen / red
Number of ports1
Cross-sectional area (L1, L2, L3, N, PE, ) (min.)1.5 mm2 solid / flexible
Cross-sectional area (L1, L2, L3, N, PE, ) (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rails acc. to EN 60715
Enclosure materialthermoplastic, red, UL 94 V-0
Place of installationindoor installation
Degree of protectionIP 20
Capacity4 module(s), DIN 43880
ApprovalsKEMA
Type of remote signalling contactchangeover contact
Switching capacity (a.c.)250 V / 0.5 A
Switching capacity (d.c.)250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible

DEHNvap DVA CSP 1P 50 S FM, Part No. 900366


DEHNvap DVA CSP 1P 50 S FM

Basic circuit diagram DVA CSP 1P 50 S FM

Dimension drawing DVA CSP 1P 50 S FM

  • Prewired combined lightning current and surge arrester, energy-coordinated with power supply systems for cell sites (DEHNvap CSP … Cell Site Protection)
  • Spark gap technology with a width of only 1 module/pole allows compact and space-saving design
  • Combined lightning current and surge arrester for use in single phase TT and TN systems (1+1 configuration) for protecting 230 V power supply systems of cell sites

Technical data

SPD according to EN 61643-11 / … IEC 61643-11type 1 + type 2 / class I + class II
Energy coordination with terminal equipment (≤ 10 m)type 1 + type 2 + type 3
Nominal voltage (a.c.) (UN)230 V (50 / 60 Hz)
Max. continuous operating voltage (a.c.)[L-N]/[N-PE] (UC)255 V (50 / 60 Hz)
Lightning impulse current (10/350 μs) [L-N]/[N-PE] (Iimp)25 / 50 kA
Specific energy [L-N]/[N-PE] (W/R)156.25 kJ/ohms / 625.00 kJ/ohms
Nominal discharge current (8/20 μs) (In)25 / 50 kA
Voltage protection level [L-N] / [N-PE] (UP)≤ 1.5 kV / ≤ 1.5 kV
Follow current extinguishing capability [L-N]/[N-PE] (Ifi)25 kArms / 100 Arms
Follow current limitation/Selectivityno tripping of a 32 A gGfuse up to 25 kArms (prosp.) Response time
Response time [L-N] (tA)≤ 100 ns
Max. backup fuse (L) up to IK> 25 kArms250 A gG
Temporary overvoltage (TOV) [L-N] (UT) – Characteristic440 V / 120 min. – withstand
Temporary overvoltage (TOV) [N-PE] (UT) – Characteristic1200 V / 200 ms – withstand
Additional abnormal voltage test: 485 V AC / 50 Hz for 24 hwithstand
Let-Through-Energy in combination with an MOV S20K275 (Iimp =2.5 … 25 kA)< 0.5 J
Safe behavior at U = 320 V and ISCCR = 13.5 kA in combination with a fuse 63 A gGwithstand
Operating temperature range [parallel]/[series] (TU)-40°C…+80°C
Operating state/fault indicationgreen / red
Number of ports1
Cross-sectional area (L1, L2, L3, N, PE, ) (min.)1.5 mm2 solid / flexible
Cross-sectional area (L1, L2, L3, N, PE, ) (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rails acc. to EN 60715
Enclosure materialthermoplastic, red, UL 94 V-0
Place of installationindoor installation
Degree of protectionIP 20
Capacity2 module(s), DIN 43880
ApprovalsKEMA
Type of remote signalling contactchangeover contact
Switching capacity (a.c.)250 V / 0.5 A
Switching capacity (d.c.)250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible