FDB5-24


Description

Flameproof surge arrester for protecting two 24 V interfaces in potentially explosive atmospheres. Application: Flow sensors, temperature sensors.

  • Easy to mount on the spare cable gland of field devices
  • Flexible use in Ex(i) and Ex(d) circuits
  • Installation in conformity with the lightning protection zone concept at the boundaries from 0B-2 and higher
SEND INQUIRY
PDF Download
Type FDB5-24
SPD according to EN 61643-21 / IEC 61643-21 type 2 / class II
Nonimal voltage Un 24 V
Max. continuous operating a.c. voltage Uc 25.4 V
Max. continuous operating d.c. voltage Uc 36 V
Nominal current IL 0.55 A
D1 Lightning impulse current (10/350 μs) line-PG (Iimp) 1.5 kA
C2 Total nominal discharge current (8/20 μs) (In) 20 kA
C2 Nominal discharge current (8/20 μs) line-PG (In) 10 kA
Voltage protection level line-line for In C2 (Up) ≤ 65 V
Voltage protection level line-PG for In C2 (Up) ≤ 2000 V
Voltage protection level line-line at 1 kV/μs C3 (Up) ≤ 50 V
Voltage protection level line-PG at 1 kV/μs C3 (Up) ≤ 1200 V
Capacitance line-line (C) ≤ 2 nF
Capacitance line-PG (C) ≤ 15 pF
Range of operating temperatures (TU) -40/+80°C
Degree of protection IP67
For mounting on (field / device side) M20 x 1.5 male thread
Connection connecting lines (1.3 mm2)
Length of the connecting line Approx. 150 mm
Earthing via connecting line
Enclosure material stainless steel

Dimensions-and-Basic-circuit-diagram-SPDs-for-Field-Devices-FDB5-24