Type 1+2 T1+T2 Class B+C Class I+II PV Surge Protective Device DC SPD 1000V, 1500V
Type 1+2, T1+T2, Class B+C, Class I+II PV DC Surge Protective Device SPD is consisting of a base part and 3 plug-in high energy MOV protection modules. Remote signalling contact for monitoring device is for options. With thermal disconnect mechanical inside for fault indication by red indicator flag.
- Ucpv: 1000Vdc/1500Vdc
- T1+T2, Class B+C, Class I+II, Iimp(10/350μs): 6,25kA, Itotal12,5kA, In(8/20μs): 20kA, Imax(8/20μs): 40kA
- High energy MOV, plug-in module design, easy replacement.
- With thermal disconnect mechanical inside for fault indication by red indicator flag. Visual Indication: Green=OK, Red=Replace
- Floating changeover contact for monitoring device for options
- Voltage protection level (Up): <5,2kV
- IP20 Degree of Ingress Protection
- Standards: EN 50539-11:2013 Low-voltage surge protective devices – Surge protective devices for specific application including d.c. – Part 11: Requirements and tests for SPDs in photovoltaic applications
- Standards: IEC 61643-31:2018 Low-voltage surge protective devices – Part 31 Requirements and test methods for SPDs for photovoltaic installations
- 1000Vdc, 1500Vdc approved by TUV, CB, CE
- Make the SPD with true RoHS material.
- 5 years warranty
T1+T2 PV Surge Protective Device FLP series are suitable for photovoltaic applications. These SPDs are designed and tested according to PV T1+T2 classification from IEC 61643-31 & EN 50539-11 standard.
FLP-PVXXX-(S) | 600 | 1000 | 1200 | 1500 |
IEC Electrical | ||||
Maximum Continuous Operating DC Voltage (DC+) – PE, (DC-) – PE Ucpv (DC+) – (DC-) Ucpv | 600V – | 1000V 1000V | 1200V 1200V | 1500V 1500V |
Nominal Discharge Current (8/20 μs) In | 20 kA | |||
Impulse Discharge Current (10/350 μs) Iimp | 6.25 kA | |||
Total Discharge Current (10/350 μs) ITotal | 12.5 kA | |||
Total Discharge Current (8/20 μs) ITotal | 40 kA | |||
Voltage Protection Level (DC+) – PE, (DC-) – PE Up (DC+) – (DC-) Up | 2200V – | 4000V 4000V | 4400V 4400V | 5200V 5200V |
Response Time tA | < 25 ns | |||
Short-Circuit Current Rating ISCPV | 2000 A | |||
Number of Ports | 1 |
Mechanical & Environmental | |
Operating Temperature Range Ta | -40 ºF to +158 ºF [-40 ºC to +70 ºC] |
Permissible Operating Humidity RH | 5%…95% |
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500 m … 2000 m |
Terminal Screw Torque Mmax | 39.9 Ibf·in [4.5 Nm] |
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) 35 mm2 (Solid, Stranded) / 25 mm2 (Flexible) |
Mounting | 35 mm DIN Rail, EN 60715 |
Degree Of Protection | IP 20 (built-in) |
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 |
Thermal Protection | Yes |
Operating State / Fault Indication | Green ok / Red defect |
Remote Contacts (RC) | Optional |
RC Switching Capacity | AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
RC Conductor Cross Section (max) | 16 AWG (Solid) / 1.5 mm2 (Solid) |
Order Information | ||||
Order Code | 600 | 1000 | 1200 | 1500 |
FLP-PVXXX | 0760025 | 0710235 | 0712235 | 0715231 |
FLP-PVXXX-(S) (with remote contacts) | 0760026 | 0710236 | 0712236 | 0715232 |
FLP-PVXXX/0 (spare modules) | 0760002 | 0710202 | 0712202 | 0715202 |
FAQ
Q1: Selection of surge protector
Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC 61643-31 & EN 50539-11 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of IEC 61643-31 & EN 50539-11 is Itotal (10/350) 12.5 ka, and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.
Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?
A2: We are a lightning surge protectors manufacturer.
Q3: Warranty and services:
A3:1. Warranty 5 years
2. lightning surge protectors products and accessories have been tested 3 times before ship out.
3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.
Q4: How can I get some lightning surge protectors samples?
A4: We are honored to offer you lightning surge protectors samples, pis contact our staff and leave detailed contact information, we promise to keep your information confidential.
Q5: Is the sample available and free?
AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.
Q6: Do you accept customized order?
A6: Yes, we do.
Q7: What’s the delivery time?
A7: It usually takes 7-15days after confirming payment, but the specific time should be based on the order quantity.
Packaging & Shipping