Mbusak macem-macem merek T1 + T2, Kelas B + C, Kelas I + II, Iimp 25kA perangkat proteksi gelombang SPD


 1. Dehn (Jerman)

Dehn kilat saiki lan gelombang arrester DV M TT 2P 255 FM T1 + T2, Kelas B + C, Kelas I + II piranti proteksi gelombang SPD

Dehn DV M TT 2P 255 FM bagean no. 951 115

Diagram sirkuit dhasar Dehn DV M TT 2P 255 FM

Dehn DV M TT 2P 255 FM bagean no. 951 115 pic1

Dehn DV M TT 2P 255 FM bagean no. 951 115 pic2

Jinis: DV M TT 2P 255 FM, No Part: 951115

  • Arus bledhek gabungan lan arus arrester sing dipasang ing bunder gabungan, kalebu bagean dhasar lan modul proteksi plug-in
  • Kasedhiyan sistem maksimum amarga Aliran RADAX tindakake watesan saiki
  • Ora ana tripping 20 A gL / gG sekering nganti 50 kArms arus pendek
  • Kapasitas arus kilat saiki: 50 kA (10/350 )s)
  • Ngidini kanggo nglindhungi peralatan terminal
  • Indikasi kesalahan kanthi tandha abang ing jendela inspeksi
  • Ganti modul proteksi kanthi gampang nganggo sistem kunci modul kanthi ngeculake tombol

Arus kilat gabungan lan arus arrester gabungan kanggo nglindhungi sistem TT fase lan TN (sirkuit "1 + 1") saka lonjakan

SPD miturut EN 61643-11 / IEC 61643-11jinis 1 + jinis 2 / kelas I + kelas II
Koordinasi energi karo peralatan terminal (<10 m)ketik 1 + jinis 2 + jinis 3
Voltase nominal (ac) (UN)230 V (50/60 Hz)
Maks. voltase operasi terus (ac) [LN] (UC)264 V (50/60 Hz)
Maks. voltase operasi terus-terusan (ac) [N-PE] (UC (N-PE))255 V (50/60 Hz)
Arus impuls kilat (10/350 μs) [L + N-PE] (ITotal)50 kA
Arus impuls kilat (10/350 μs) [LN] / [N-PE] (Iimp)25/50 kA
Arus debit nominal (8/20 μs) [LN] / [N-PE] (In)25/50 kA

Dehn DV Series 255 V ac Rating Maksimum Maksimum 100kA Arrester Kilat Mundhak Saiki, DIN Rail Mounting

Dehn DV Series 255 V ac Rating Maksimum Maksimum 100kA Arrester Kilat Mundhak Saiki, DIN Rail Mounting

Diagram sirkuit dhasar DV M TT 255 FM

Jinis: DV M TT 255 FM, No Part: 951315

SPD miturut EN 61643-11 / IEC 61643-11jinis 1 + jinis 2 / kelas I + kelas II
Koordinasi energi karo peralatan terminal (≤ 10 m)ketik 1 + jinis 2 + jinis 3
Voltase nominal (ac) (UN)230/400 V (50/60 Hz)
Maks. voltase operasi terus (ac) [LN] (UC)264 V (50/60 Hz)
Maks. voltase operasi terus-terusan (ac) [N-PE] (UC (N-PE))255 V (50/60 Hz)
Arus impuls kilat (10/350 μs) [L1 + L2 + L3 + N-PE] (ITotal)100 kA
Arus impuls kilat (10/350 μs) [LN] / [N-PE] (Iimp)25/100 kA
Arus debit nominal (8/20 μs) [LN] / [N-PE] (In)25/100 kA

Dehn 255 V ac 100kA Arrester Kilat DV, Pemasangan Rel DIN

Dehn DV M TNS 255 (951 400)

Diagram sirkuit dhasar DV M TNS 255

Jinis: DV M TNS 255, Bagian No .: 951400

SPD miturut EN 61643-11 / IEC 61643-11jinis 1 + jinis 2 / kelas I + kelas II
Koordinasi energi karo peralatan terminal (≤ 5 m)ketik 1 + jinis 2 + jinis 3
Voltase nominal (ac) (UN)230/400 V (50/60 Hz)
Maks. voltase operasi terus-terusan (ac) (UC)264 V (50/60 Hz)
Saiki impuls kilat (10/350 )s) [L1 + L2 + L3 + N-PE] (ITotal)100 kA
Arus impuls kilat (10/350 )s) [L, N-PE] (Iimp)25 kA
Arus debit nominal (8/20 )s) [L / N-PE] / [L1 + L2 + L3 + N-PE] (In)25/100 kA

2. Phoenix (Jerman)

Arus kilat Phoenix lan arrester gelombang T1 + T2, Kelas B + C, piranti proteksi gelombang kelas I + II SPD

FLT-SEC-P-T1-1S-264-50-FM

Phoenix FLT-SEC-P-T1-1S-350-25-FM

Perlindhungan lonjakan Phoenix FLT-SEC-P-T1-1S-350-25-FM, pesenan no. 2905415 pic1

Perlindhungan gelombang Phoenix flt-SEC-P-T1-1S-35025-FM, pesenan no. 2905415 pic2

Perlindhungan mundhak kanggo pasokan listrik
Tipe gabungan 1/2 piranti protèktif - FLT-SEC-P-T1-1S-350/25-FM, pesenan no. 2905415

  • Spark gap ora duwe tindakake saiki
  • Bebas arus bocor, cocog digunakake ing wilayah pra-meter
  • Tegangan terus-terusan 350 V AC kanggo jaringan AC 230/400 V kanthi fluktuasi tegangan tinggi
  • Pluggable
  • Tingkat proteksi voltase sedheng 1.5 kV
  • Indikator status mekanik, optik
  • Kanthi kontak pratondo remot ngambang

Klasifikasi tes IECI / II, T1 / T2
Tegangan nominal UN240 V AC (TN-S)

240 V AC (TT)

Cara nglindhungiLN / L-PE / N-PE
Tegangan operasi maksimum maksimum UC350 V AC
Impulse debit saiki akuimp (10/350) s25 kA / 25 kA / 100 kA
Arus debit nominal In (8/20) s25 kA / 25 kA / 100 kA
Maks. debit saiki akumax (8/20) s50 kA

3. Raycap (Jerman) & Iskra Zascite (Slovenia)

Perlindhungan kilat lan overvoltage Kelas I Kelas II Tipe 1 Tipe 2 Tipe 4CA

Lampu kilat lan Perlindhungan Overvoltage Raycap 25 kA Series ProTec T1HS 3 + 1

Perlindhungan Lightning lan Overvoltage 25 kA Series ProTec T1HS 3 + 1 diagram Sirkuit

Raycap T1 + T2 surge arrester ProTec T1HS-300-3 + 1-R Kode Pesenan 590307

Ketik: ProTec T1HS-300-3 + 1-R, Kode Pesenan: 59.0307

  • Lokasi Panggunaan: Papan Distribusi Utama
  • Sistem Jaringan: TT, TN-S
  • Cara Proteksi: LN, N-PE
  • Kategori IEC / EN / UL: Kelas I + II, Tipe 1 + 2, Tipe 4CA
  • Teknologi: Sato
  • Bebas Saiki Mbocor: Ya
  • Omah: Desain Pluggable
  • Kepatuhan: IEC 61643-11: 2011; EN 61643-11: 2012; UL 1449 Edhisi 4

Tegangan AC Nominal (50 / 60Hz) Uo /Un240 V
Tegangan Operasi Maksimum (AC) (LN) / (N-PE) Uc300 V / 305 V
Nominal Saiki Ngirim (8/20 μs) (LN) / (N-PE) In25 kA / 100 kA
Saiki Mbuwang Maksimum (8/20 μs) (LN) / (N-PE) Imax65 kA / 130 kA
Impulse Discharge Current (10/350 μs) (LN) / (N-PE) Iimp25 kA / 100 kA
Energi Sprcific (LN) / (N-PE) W / R156.2kJ / Ω / 2500kJ / Ω
Ngisi daya (LN) / (N-PE) Q12.5 Minangka / 50 Minangka
Tingkat Perlindhungan Tegangan (LN) / (N-PE) Up1500 V / 1500 V
Dinilai Beban SaikiL100 A
Wektu Respon (LN) / (N-PE) tA<100 ns / <100 ns
Proteksi Overcurrent (max)315 gG
Rating Saiki Short-Circuit (AC) ISCCR50 kA
Tututi Rating Interrupt Saiki (N-PE) Ifi100 ARMS
TOV Tahan 120min (LN) UT442 V
TOV Tahan 200ms (N-PE) UT1200 V
Jumlah port1
Tegangan Operasi Maksimum (AC) (L - N) / (N - G) MCOV300 V / 305 V
Ukur Watesan voltase (L - N) / (N - G) MLV1280 V / 1000 V
Nominal Saiki Ngirim (8/20 μs) (L - N) / (N - G) Ing20 kA
Operasi Suhu Operasi Ta-40 oF nganti +185 oF [-40 oC nganti +85 oC]
Kelembapan Operasi sing Diidini RH5%… 95%
dhuwur13123 ft [4000 m]
Torsi Sekrup Terminal Mmax39.9 Ibf · ing [4.5 Nm]
Konduktor Salib Konduktor (maks)2 AWG (Solid, Straded) / 4 AWG (Fleksibel)
35 mm2 (Padat, terdampar) / 25 mm2 (Fleksibel)
soyo tambahRel DIN 35 mm, EN 60715
Degree ProtectionIP 20 (internal)
Material HousingThermoplastic: Gelar Ngusir UL 94 V-0
Perlindhungan termalYa
Indikator Operasi / KesalahanGendéra Ijo / Ora Gendera Ijo
Kontak Jauh (RC)pilihan
Kapasitas Ngalih RCAC: 250 V / 1A, 125 V / 1 A; DC: 48 V / 0.5 A, 24 V / 0.5 A, 12 V / 0.5 A.
Seksi Salib Konduktor RC (maks)16 AWG (Solid) / 1.5 mm2 (Padhet)

4. Citel (Prancis)

Tipe 1 + 2 + 3 AC Surge Protector DS250VG seri

Citel T1 + T2 + T3 piranti proteksi gelombang SPD DS250VG-300 Bagéan nomer 2577 pic1

DS250VG-300DE Tipe 1 + 2 pelindung gelombang AC 1 tiang

Perangkat proteksi lonjakan Citel T1 + T2 SPD DS250VG-300 Bagéan nomer 2577 pic2

Model CITEL: DS250VG-300, Nomer bagean: 2577

  • Tipe 1 + 2 + 3 Protector munggah
  • 25 kA ing 10/350 μs impuls
  • Tegangan endhek UP
  • Putus internal, indikator status lan sinyal jarak jauh
  • Dioptimalake dadi TOV
  • IEC 61643-11 lan EN 61643-11 kepatuhan
  • UL 1449 ed. 4 pangenalan

DescriptionTipe 1 + 2 + 3 AC protector siji-tiang
Network230 / 400 V
Maks. Tegangan operasi AC (UC)255 Wac
Charasteristics Voltage Over Voltage (TOV) - 5 sec. (UT)335 Vac tahan
Charasteristics Voltage Over Voltage (TOV) - 120 mn (UT)440 Vac tahan
Sisa saiki - Saiki bocor ing Uc (Ipe)Ana
Maks. Muat saiki (yen sambungan sambungan) (IL)100 A
Tututi saiki (If)Ana
Arus debit nominal - 15 x 8/20 ul s impulses (In)30 kA
Maks. debit saiki -max. tahan @ 8/20 bys kanthi tiang (Imax)70 kA
Impulse current by pou - maks. tahan 10 / 350µs (Iimp)25 kA
Energi spesifik miturut tiang (W / R)156 kJ / ohm
Tahan ing bentuk gelombang Kombinasi - Tes Kelas III (Uoc)20 kV
Tingkat proteksi @ In (Up-ing)1.1 kV
Tingkat proteksi (Up)1.5 kV
Arus sirkuit cendhak sing bisa ditampa (Isccr)50000 A
Pemisah Thermalinternal
TumindakJinis sekring gG - 315 A
Pemecah kesalahan dhasar instalasiJinis> utawa telat
dimensindeleng diagram
Sambungan karo JaringanKanthi terminal sekrup: 6-35 mm2 / kanthi bis
Indikator sambungan1 indikator mekanik
Sinyal adoh saka sambunganoutput ing kontak pangowahan
soyo tambahRel simetris 35 mm (EN60715)
suhu Operating-40 / + 85 ° C
Rating proteksiIP20
Bahan omahTermoplastik UL94-V0
Selaras karo standarIEC 61643-11 / EN 61643-11 / UL1449 ed.4
CertificationUL / CSA / EAC
Nomer part2577

5. Saltek (Ceko)

OEM kanggo Schneider, ayo njupuk conto Schneider kayata.

SPD Tipe 1 - Kilat Saiki Arrester FLP-25-T1-V (S) -3 + 1, nomer pesenan .: A05305

FLP-25-T1-V (S) -3 + 1 nomer pesenan A05305

Diagram sirkuit dhasar FLP-25-T1-V (S) -3 + 1 nomer urut-urutan A05305

Kilat Saiki Arrester FLP-25-T1-V (S) -3 + 1, nomer pesenan. A05305

Penangkal Saiki Lightek Saltek FLP-25-T1-V (S) -3 + 1 nomer pesen A05305

modul pluggable, sinyal kesalahan visual, kunci modul

  • kombinasi arrester petir kinerja dhuwur telung tiang lan kesenjangan percikan efisiensi enkapsulasi, disambungake ing mode 3 + 1
  • instalasi ing wates zona LPZ 0 lan LPZ 1 utawa luwih dhuwur, utamane menyang papan distribusi utama
  • kanggo nglindhungi pengaruh serangan kilat langsung utawa ora langsung ing macem-macem aplikasi - omah, kantor lan bangunan industri
  • koordinasi karo SPD Type 2 (SLP-275 V) sanajan tanpa induktor misahake gelombang
  • sinyal kesalahan kesalahan adoh (S)
  • ora ana arus bocor

Tegangan nominal Un230 V AC
Voltase operasi maksimum LN Uc260 V AC
Tegangan operasi maksimum N-PE Uc255 V AC
Nomer saiki mbukak kanggo sambungan "V" IL125 A
Saiki impuls kilat (10/350 μs) LN Iimp25 kA
Saiki impuls kilat (10/350 μs) N-PE Iimp100 kA
Mode level proteksi voltase LN Up1,5 kV
Mode level proteksi voltase N-PE Up1,5 kV
Mode level proteksi voltase L-PE Up2,2 kV
Kemampuan kanggo memateni N-PE I saiki ing ngisor ikifi0,1 kA
Rating arus arus pendek ISCCR50 kA
Perlindhungan arus maksimum250 g / gg
Proteksi overcurrent maksimum kanggo sambungan "V"125 g / gg
Wektu respons LN ta100 ns
Wektu respons N-PE ta100 ns
Salib-bagean konduktor sing gegandhengan solid (min / max)2,5 mm2 / 50 mm2
Salib-bagean konduktor sing disambungake terdampar (min / max)2,5 mm2 / 35 mm2
Indikasi kesalahan LNlapangan pratondo abang
Indikasi kesalahan N-PEora
Indikasi jarak jauhkontak pangowahan bebas potensial
Kontak pratondho adoh250V / 0,5A AC, 250V / 0,1A DC
Penampang konduktor indikasi remot1,5 mm2
Degree of protectionIP 20
Range suhu operasi (min / max)-40 ° C / 80 ° C
soyo tambahRel DIN 35 mm
Miturut standarEN 61643-11: 2012, IEC 61643-11: 2011 / T1

 6. Weidmuller (Jerman)

Weidmuller kilat arrester VPU I 1 + 1-R LCF 280V / 25kA (Pesen no. 1351740000)

Weidmuller kilat arrester VPU I 1 + 1-R LCF 280V 25kA

Diagram sirkuit dhasar Weidmuller VPU I 1 + 1-R LCF 280V-25kA

Weidmuller kilat arrester VPU I 1 + 1-R LCF 280V 25kA Pesenan no. 1351740000

  • Jupuk petir kilat I / II kanggo nggunakake hulu meter listrik
  • Kanthi 25 kA (10/350 µs) cocog kanggo zona protèktif I, II, III lan IV (LPL I / II / III / IV)
  • Kanthi fungsi ngawasi remot, siji kontak pangowahan
  • Diuji miturut IEC 61643-11 kanggo nglindhungi tipe I lan II
  • Arrester pluggable

KoleksiVPU I 1 + 1 R LCF 280V / 25KA
Situs jeneng1351740000
versiArrester voltase gelombang, voltase kurang, karo kontak remot, bebas bocor-saiki, fase tunggal, IT karo N, IT tanpa N, TN
Tegangan (AC)230 V
Jinis voltaseAC
Maks. voltase terus, Uc (AC)280 V
Maks. voltase terus, Uc (N-PE)260 V
Jaringan voltase sithikFase tunggal, IT kanthi N, IT tanpa N, TN
Discharge saiki akun (8 / 20µs) N-PE100 kA
Discharge saiki akumax (8 / 20µs) N-PE100 kA
Discharge saiki akun (8 / 20µs) kabel-PE25 kA
Discharge saiki akumax (8 / 20µs) kabel-PE100 kA
Saiki tes petir Iimp (10/350 )s) (L-PE)25 kA
Saiki tes petir, akuimp (10/350 )s) (N-PE)100 kA
Jangkauan frekuensi, maks.60 Hz
Jangkauan frekuensi, min.50 Hz
FuseOra perlu Fuse ≤250 A gG, 250 A gL (yen sekring> 250 A)
Rating arus sirkuit cendhak (ISCCR)25 kA
Kapabilitas pemadam saiki sing diterusake IfiOra kasedhiya amarga alasan teknis
StandardsIEC61643-11, EN61643-11
Koordinasi energi (≤10 m)Tipe I, Tipe II, Tipe III
Tingkat proteksi Up ing akuN (L / N-PE)1.6 kV
Tingkat proteksi Up ing akuN (N-PE)1.6 kV
Saiki bocor ing Un1 µA
Voltase gelombang sementara (over-voltage) - TOV438 V
Cagak cagak1
Dinilai beban saiki akuL125 A
Kategori syarat Syarat acc. nganti IEC 61643-11Tipe I, Tipe II
Kelas syarat, acc. nganti EN 61643-11T1, T2
Respon wektu≤ 100 ns
Kontak sinyal250 V 1A 1CO
Cocog kanggoInstalasi count-in (bocor saiki gratis)

Asil analisis utami:

Dehn lan Phoenix nggunakake celah sparks encapsulated kanggo nggawe T1 (T1 + T2) SPD.

Raycap, Citel, Saltek lan Weidmuller nggunakake varistors energi plus tabung debit gas (GDT) kanggo nggawe T1 (T1 + T2) SPD.