DC 48V, 65V, 75V doimiy tokni himoya qilish moslamasi SPD kuchlanish himoyasi 1 + 2, T1 + T2, 2-toifa, T2, B + C, S sinf
Fotovoltaik PV quyosh va doimiy oqimlari uchun DC 48V, 65V, 75V DC kuchlanishni himoya qilish moslamasi SPD Surge Protector Type 1 + 2, T1 + T2, Type 2, T2, Class B + C, Class C, Iimp = 4 kA dan 25 kA gacha (10/350 ms), Imax = o'zgaruvchan aloqa bilan 40 kA dan 100 kA (8/20 ms) gacha.
- Monoblok va ulanadigan dizayn.
- Vizual ko'rsatma: Yashil = OK, Qizil = O'zgartirish.
- Vaziyatni kuzatishni osonlashtirish uchun signalni masofadan boshqarish aloqasi.
- O'zini himoya qilish uchun tezkor termal javob.
- Kuchlanishdan himoya darajasi (Yuqoriga): 0.5kV / 0.3kV.
- 1-toifa, T1, B sinf, I sinf Iimp (10/350 ms): 4 kA dan 25 kA gacha.
- 2-toifa, T2, C sinf, II sinf, Imax (8 / 20ms): 40 kA dan 100 kA gacha.
- Qayta tiklash: 48Vdc
- Ucdc: 65Vdc / 75Vdc.
DC 48V, 65V, 75V DC kuchlanishli himoya qilish moslamasi SPD kuchlanish himoyasi 1 + 2, T1 + T2, 2-toifa, T2, B + C, C sinflari fotovoltaik ilovalar uchun javob beradi. Ushbu SPDlar IEC / EN 1-2 / IEC / EN 2-61643 dan DC T11 + T61643 & T41 tasnifi bo'yicha ishlab chiqilgan va sinovdan o'tgan.
48Vdc quvvatli kuchlanishni himoya qiluvchi | FLP25-DC75 / 1 (S) | FLP25-DC75 / 1 (S) +1 | FLP7-DC65 / 1 (S) | FLP7-DC65 / 2 (S) | SLP40-DC65 / 1 (S) | SLP40-DC65 / 2 (S) |
IEC Electric | ||||||
Nominal operatsion doimiy voltaj Uo / Un | 48 Vd | |||||
Ulanish tartibi | DC + / PE yoki DC- / PE | DC + / DC- va DC + / PE | DC + / PE yoki DC- / PE | DC + / DC- va DC + / PE | DC + / PE yoki DC- / PE | DC + / DC- va DC + / PE |
Himoya rejimi (lar) i | CM | CM / DM | CM | CM | CM | CM |
Maks. PV ish kuchlanishi Ucdc | 75 Vd | 75 Vd | 65 Vd | 65 Vd | 65 Vd | 65 Vd |
Qoldiq oqim - Uc Ipe-da qochqin oqimi | <0.1 mA | holda | <0.1 mA | <0.1 mA | <0.1 mA | <0.1 mA |
Nominal deşarj oqimi - 15 x 8/20 ms impulslar In | 25 ta | 25 kA / 50 kA | 20 ta | 20 ta | 20 ta | 20 ta |
Maksimal deşarj oqimi Maks. 8/20 ms Imaxga chidamli | 100 ta | 100 ta | 50 ta | 50 ta | 40 ta | 40 ta |
Impulse deşarj oqimi Maks. 10/350 ms Iimp ga chidamli | 25 ta | 25 kA / 50 kA | 7 ta | 7 ta | 4 ta | 4 ta |
Impulse deşarj oqimi Maks. 10/350 mS ga teng | - | 50 ta | - | 14 ta | - | 8 ta |
Kuchlanishni himoya qilish darajasining yuqoriligi | 0.5 kV | 0.5 kV / 1.5 kV | 0.3 kV | 0.3 kV | 0.3 kV | 0.3 kV |
Javob vaqti tA | <25 ns | |||||
Portlar soni | 1 |
Mexanik va atrof-muhit | |
Ishlash harorati diapazoni Ta | -40 ºF dan +158 ºF [-40 ºC dan +70 ºC gacha] |
RHning ruxsat etilgan ishchi namligi | 5%… 95% |
Atmosfera bosimi va balandligi | 80k Pa… 106k Pa / -500 m… 2000 m |
Terminal burama momenti Mmax | 39.9 Ibf · [4.5 Nm] da |
Supero'tkazuvchilar kesimi (maksimal) | 2 AWG (qattiq, torli) / 4 AWG (egiluvchan) 35 mm2 (qattiq, torli) / 25 mm2 (egiluvchan) |
o'rnatish | 35 mm DIN temir yo'li, EN 60715 |
Himoya darajasi | IP 20 (o'rnatilgan) |
Uy-joy materiallari | Termoplastik: UL 94 V-0 söndürme darajasi |
Termal himoya | ha |
Ishlayotgan holat / Nosozlik ko'rsatkichlari | Yashil ok / qizil nuqson |
Masofaviy aloqalar (RC) | ixtiyoriy |
RC-ni almashtirish imkoniyati | AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
RC Supero'tkazuvchilar kesimi (maksimal) | 16 AWG (Qattiq) / 1.5 mm2 (Qattiq) |
Buyurtma ma'lumot | ||||||
Buyurtma kodi | FLP25-DC75 / 1 (S) | FLP25-DC75 / 1 (S) +1 | FLP7-DC65 / 1 (S) | FLP7-DC65 / 2 (S) | SLP40-DC65 / 1 (S) | SLP40-DC65 / 2 (S) |
masofaviy kontaktlarsiz | 2507511 | 2507513 | 0706511 | 0706521 | 4006511 | 4006521 |
masofaviy kontaktlar bilan | 2507512 | 2507514 | 0706512 | 0706522 | 4006512 | 4006522 |
zaxira modullar | - | - | 0706501 | 0706501 | 4006501 | 4006501 |
FAQ
1-savol: Dalgalanish himoyasini tanlash
Al: DC kuchlanishidan himoyalanadigan qurilmaning darajasi T2 (odatda chaqmoqdan himoya deb ataladi) bo'linmaning birlashmasiga o'rnatilgan IEC 61643-11 / EN 61643-11 / EN 50539 bo'linishidan himoya qilish nazariyasiga muvofiq baholanadi. Texnik talablar va funktsiyalar bir-biridan farq qiladi. Birinchi darajali chaqmoqlarni himoya qilish moslamasi 0-1 zonasi o'rtasida o'rnatiladi, oqim talablari yuqori, IEC 61643-11 / EN 61643-11 / EN 50539 minimal talablari 40 ka (8/20), ikkinchisi va uchinchi darajalar asosan 1-2 va 2-3 zonalar o'rtasida o'rnatiladi haddan tashqari kuchlanishni bostirish uchun.
2-savol: Siz chaqmoqni himoya qilish fabrikasisiz yoki chaqmoqni himoya qiladigan savdo shirkatisiz?
A2: Biz chaqmoqni himoya qiladigan ishlab chiqaruvchilarmiz.
3-savol: Kafolat va xizmatlar:
A3: 1. Kafolat 5 yil
2. chaqmoqni himoya qilish vositalari va aksessuarlari kema chiqishidan oldin 3 marta sinovdan o'tkazildi.
3. Biz eng yaxshi sotishdan keyingi xizmat ko'rsatish guruhiga egamiz, agar biron bir muammo yuzaga kelsa, bizning jamoamiz buni siz uchun hal qilish uchun qo'limizdan kelganini qiladi.
4-savol: Qanday qilib chaqmoqni himoya qiladigan ba'zi namunalarni olishim mumkin?
A4: Biz sizga chaqmoqni himoya qiladigan namunalarni taqdim etishdan mamnunmiz, xodimlarimiz bilan bog'laning va batafsil aloqa ma'lumotlarini qoldiring, biz sizning ma'lumotlaringizni sir tutishga va'da beramiz.
5-savol: Namuna mavjudmi va bepulmi?
AS: Namuna mavjud, ammo namunaviy narx siz to'lashi kerak. Namunaning narxi keyingi buyurtmadan keyin qaytariladi.
Q6: Siz tayyorlangan buyurtmani qabul qilasizmi?
A6: Ha, qilamiz.
7-savol: Yetkazib berish muddati qancha?
A7: To'lovni tasdiqlaganidan keyin odatda 7-15 kun davom etadi, ammo ma'lum bir vaqt buyurtma miqdori asosida bo'lishi kerak.