loyiha ta'rifi

FLP50GR-600/2 + 1


Tavsif

TT va TN tizimlarini ("2 + 1" zanjiri) kuchlanishdan himoya qilish uchun ajralmas korpusli muvofiqlashtirilgan chaqmoq oqimi va kuchlanishni to'xtatuvchi.

  • Muvofiqlashtirilgan uchqun oralig'idagi chaqmoq oqimi va kuchlanishni to'xtatuvchi
  • RADAX Flow tufayli tizimlarning maksimal mavjudligi joriy cheklovlarga amal qiladi
  • Terminal uskunalarini himoya qilishga qodir
TANLOVGA OLING
PDF ko'chirib olish
ShriftFLP50GR-600/2 + 1
EN 61643-11 / IEC 61643-11 bo'yicha SPD1-toifa / I sinf
Nominal AC kuchlanish (Un)480 V o'zgaruvchan (50/60 Hz)
Maks. uzluksiz ishlaydigan AC kuchlanish [LN] (Uc)600 V o'zgaruvchan (50/60 Hz)
Maks. uzluksiz ishlaydigan AC kuchlanish [N-PE] (Uv (N-PE))255 V o'zgaruvchan (50/60 Hz)
Chaqmoq impuls oqimi (10 / 350ms) [L1 + L2 + N-PE] (Ijami)150 ta
Maxsus energiya [L1 + L2 + N-PE] (W / R)2,5 MJ / ohm
Chaqmoq impuls oqimi (10 / 350ms) [LN] / [N-PE] (Ishayton)50 kA / 100 kA
Maxsus energiya [LN] / [N-PE] (W / R)625,00 kJ / ohm / 2,5 MJ / ohm
Nominal deşarj oqimi (8 / 20ms) [LN] / [N-PE] (In)50 kA / 100 kA
Kuchlanishdan himoya darajasi [LN] / [N-PE] (Up)2,0 kV / 1,5 kV
Hozirgi söndürme qobiliyatiga amal qiling (Ifi)50 tarms / 100 A.rms
Joriy cheklash / tanlanuvchanlikka rioya qiling20 kA gacha bo'lgan 50 A gL / gG sug'urta o'chirilmaydirms (prospekt)
Javob vaqti (tA)<100 ns
Maks. zaxira sug'urta (L) I ga qadarK = 50 kArms (ta <0,2 s)500 A gL / gG
Maks. zaxira sug'urta (L) I ga qadarK = 50 kArms (ta <5 s)315 A gL / gG
Maks. zaxira sug'urta (L) I ga qadarK > 50 kArms200 A gL / gG
Maks. zaxira sug'urta (L-L ')125 A gL / gG
Vaqtinchalik haddan tashqari kuchlanish [LN] (TOV) (UT) - xarakterli915 V / 120 min. - bardoshli
Vaqtinchalik haddan tashqari kuchlanish [N-PE] (TOV) (UT) - xarakterli1200 V / 200 milodiy. - bardoshli
Ishlash harorati diapazoni [parallel] / [qator] (TU)-40… + 80 ° C / -40… + 60 ° C
Ish holati / nosozlik ko'rsatkichi-
Portlar soni1
Kesmaning maydoni (L1, L1 ′, L2, L2 ′, N, PE, PE ') (min.)10 mm2 qattiq / moslashuvchan
Kesmaning maydoni (L1, L2, N, PE) (maksimal)50 mm2 yopiq / 35 mm2 moslashuvchan
Kesmaning maydoni (L1 ′, L2 ′, PE ') (maksimal)35 mm2 yopiq / 25 mm2 moslashuvchan
O'rnatish uchun35 mm DIN relsli aks. EN 60715 ga muvofiq
Ilova materialitermoplastik
O'rnatish joyiichki o'rnatish
Himoya darajasiIP20
sig'im6 ta modul (lar), DIN 43880
TasdiqlashlarCE

O'lchovlar va-Asosiy-sxemasi-SPD-FLP50GR-600-2 + 1