DC 48V, 65V, 75V DC Surge Protective Device SPD Surge Protector Type 1+2, T1+T2, Type 2, T2, Class B+C, Class C
For Photovoltaic PV solar and DC applications DC 48V, 65V, 75V DC Surge Protective Device SPD Surge Protector Type 1+2, T1+T2, Type 2, T2, Class B+C, Class C, Iimp = from 4 kA to 25 kA (10/350 μs), Imax = from 40 kA to 100 kA (8 /20 μs), with changeover contact.
- Monoblock and Pluggable Design.
- Visual Indication: Green=OK, Red=Replace.
- Remote alarm contact to make status monitoring easy.
- Quick thermal response for self-protection.
- Voltage protection level (Up): 0.5kV/0.3kV.
- Type 1, T1, Class B, Class I Iimp(10/350 μs): from 4 kA to 25 kA.
- Type 2, T2, Class C, Class II, Imax(8/20μs): from 40 kA to 100 kA.
- Undc: 48Vdc
- Ucdc: 65Vdc/75Vdc.
DC 48V, 65V, 75V DC Surge Protective Device SPD Surge Protector Type 1+2, T1+T2, Type 2, T2, Class B+C, Class C is suitable for photovoltaic applications. These SPDs are designed and tested according to DC T1+T2 & T2 classification from IEC/EN 61643-11 / IEC/EN 61643-41.
48Vdc power Surge Protector | FLP25-DC75/1(S) | FLP25-DC75/1(S)+1 | FLP7-DC65/1(S) | FLP7-DC65/2(S) | SLP40-DC65/1(S) | SLP40-DC65/2(S) |
IEC Electrical | ||||||
Rated Operational DC Voltage Uo / Un | 48 Vdc | |||||
Connection mode | DC+/PE or DC-/PE | DC+/DC- and DC+/PE | DC+/PE or DC-/PE | DC+/DC- and DC+/PE | DC+/PE or DC-/PE | DC+/DC- and DC+/PE |
Protection mode(s) | CM | CM/DM | CM | CM | CM | CM |
Max. PV operating voltage Ucdc | 75 Vdc | 75 Vdc | 65 Vdc | 65 Vdc | 65 Vdc | 65 Vdc |
Residual current – Leakage current at Uc Ipe | < 0.1 mA | without | < 0.1 mA | < 0.1 mA | < 0.1 mA | < 0.1 mA |
Nominal Discharge Current – 15 x 8/20 μs impulses In | 25 kA | 25 kA/50 kA | 20 kA | 20 kA | 20 kA | 20 kA |
Maximum Discharge Current Max. withstand 8/20 μs Imax | 100 kA | 100 kA | 50 kA | 50 kA | 40 kA | 40 kA |
Impulse Discharge Current Max. withstand 10/350 μs Iimp | 25 kA | 25 kA/50 kA | 7 kA | 7 kA | 4 kA | 4 kA |
Impulse Discharge Current Max. withstand 10/350 μs Itotal | – | 50 kA | – | 14 kA | – | 8 kA |
Voltage Protection Level Up | 0.5 kV | 0.5 kV/1.5 kV | 0.3 kV | 0.3 kV | 0.3 kV | 0.3 kV |
Response Time tA | < 25 ns | |||||
Number of Ports | 1 |
Mechanical & Environmental | |
Operating Temperature Range Ta | -40 ºF to +158 ºF [-40 ºC to +70 ºC] |
Permissible Operating Humidity RH | 5%…95% |
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500 m … 2000 m |
Terminal Screw Torque Mmax | 39.9 Ibf·in [4.5 Nm] |
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) 35 mm2 (Solid, Stranded) / 25 mm2 (Flexible) |
Mounting | 35 mm DIN Rail, EN 60715 |
Degree Of Protection | IP 20 (built-in) |
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 |
Thermal Protection | Yes |
Operating State / Fault Indication | Green ok / Red defect |
Remote Contacts (RC) | Optional |
RC Switching Capacity | AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
RC Conductor Cross Section (max) | 16 AWG (Solid) / 1.5 mm2 (Solid) |
Order Information | ||||||
Order Code | FLP25-DC75/1(S) | FLP25-DC75/1(S)+1 | FLP7-DC65/1(S) | FLP7-DC65/2(S) | SLP40-DC65/1(S) | SLP40-DC65/2(S) |
without remote contacts | 2507511 | 2507513 | 0706511 | 0706521 | 4006511 | 4006521 |
with remote contacts | 2507512 | 2507514 | 0706512 | 0706522 | 4006512 | 4006522 |
spare modules | – | – | 0706501 | 0706501 | 4006501 | 4006501 |
FAQ
Q1: Selection of surge protector
Al: The grading of the DC Surge Protector Device T2 (commonly known as lightning protection) Is assessed according to the IEC 61643-11 / EN 61643-11 / EN 50539 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of IEC 61643-11 / EN 61643-11 / EN 50539 is 40 ka (8/20), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.
Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?
A2: We are a lightning surge protectors manufacturer.
Q3: Warranty and services:
A3:1. Warranty 5 years
2. lightning surge protectors products and accessories have been tested 3 times before ship out.
3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.
Q4: How can I get some lightning surge protectors samples?
A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.
Q5: Is the sample available and free?
AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.
Q6: Do you accept customized order?
A6: Yes, we do.
Q7: What’s the delivery time?
A7: It usually takes 7-15days after confirming payment, but a specific time should be based on the order quantity.
Packaging & Shipping