Type2, Class C, Class II PV Surge Protector Device SPD for PCB mount


Surge protector requirements of PV inverter manufacturers have evolved. To save space in the cabinets, the manufacturers have decided to replace DIN rail surge protectors with PCB-mounted SPDs: these ones are designed to be mounted directly inside the inverters, soldered on the internal PCB. Beyond PV applications, the AC version of these PCB-mounted SPDs could also be used for other applications, where high integration and lower costs are required (i.e charging stations for electrical vehicles). LSP has developed two dedicated product ranges: SLP20P-PV (PV power SPD) and SLP20P (AC power SPD)

The SLP20P-PV range (Type 2) is designed to protect the DC side of photovoltaic inverters.
The single-pole module must be soldered on a PCB, in parallel to the DC network.
Every configuration (Y-diagram, V diagram-circuit, Delta diagram) can be realized, related to the application.
The pin-out of the module is the same regardless of the version (T2) or Ucpv voltage, facilitating the switching from one to the other.

• For use with maximum continuous operating voltage (UCPV) up to 900 V modules
• Sensitive and reliable remote signaling contacts
• Fault indicator, green-no green
• Compact profile for printed circuit board (PCB) mounting
• In: 10 kA, Imax: 20 kA
• IEC 61643-31 compliance

Application:

In order to reach the relevant specifications, the PCB where the SLP20P or SLP20P-PV SPDs will be used must be carefully designed by the customer.

Datasheet
Manuals
SEND INQUIRY
SLP20P-PVXXX75300500600750900
Max. PV Operating Voltage (DC) Ucpv75 V300 V500 V600 V750 V900 V
Max. PV Operating Voltage (DC), [star mounting] Ucpv150 V600 V1000 V1200 V1500 V1800 V
Continuous Operating Current Icpv< 0.1 mA
Nominal Discharge Current (8/20 μs) In10 kA
Max. Discharge Current (8/20 μs) Imax20 kA
Voltage Protection Level Up0.5 kV1.1 kV1.8 kV2.0 kV2.6 kV2.8 kV
Voltage Protection Level, [star mounting] Up1.0 kV2.2 kV3.6 kV4.0 kV5.2 kV5.6 kV
Response Time tA< 25 ns
Current withstand short circuit PV ISCPV1000 A
Mechanical & Environmental
Operating Temperature Range Ta-40 ºF to +158 ºF [-40 ºC to +70 ºC]
Permissible Operating Humidity RH5%…95%
Atmospheric pressure and altitude80k Pa … 106k Pa / -500 m … 2000 m
Connection to NetworkThrough soldering pins
MountingOn Printed Circuit Board
Degree Of ProtectionIP 20 (built-in)
Housing MaterialThermoplastic: Extinguishing Degree UL 94 V-0
Disconnection indicator1 mechanical indicator by pole
Operating State / Fault IndicationGreen ok / Red defect
Remote signaling of disconnectionOutput on changeover contact
Order Information
Order Code75300500600750900
SLP20P-PVXXX200751720300172050017206001720750172090017

FAQ

Q1: Selection of surge protector

Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 40 ka (8/20), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.

Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?

A2: We are a lightning surge protectors manufacturer.

Q3: Warranty and services:

A3:1. Warranty 5 years

2. lightning surge protectors products and accessories have been tested 3 times before ship out.

3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.

Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.

Q5: Is the sample available and free?

AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.

Q6: Do you accept customized order?

A6: Yes, we do.

Q7: What’s the delivery time?

A7: It usually takes 7-15days after confirming payment, but the specific time should be based on the order quantity.

Packaging & Shipping

Packaging & Shipping

We promise to reply within 24 hours and ensure that your mailbox will not be used for any other purpose.