Class B+C Class I+II Type 1+2 T1+T2 PV Surge Protection Device DC SPD 1000V, 1500V
Class B+C, Class I+II, Type 1+2, T1+T2 PV Surge Protection Device SPD is consisting of High Energy MOV and GDT of Monoblock Multi-Pole protection modules. Remote signalling contact for monitoring device is for options. With thermal disconnect mechanical inside for fault indication by red indicator flag.
- Ucpv: 1000Vdc/1500Vdc
- T1+T2, Class B+C, Class I+II, Iimp(10/350μs): 6,25kA, Itotal12,5kA, In(8/20μs): 20kA, Imax(8/20μs): 40kA
- High energy MOV and GDT, compact, and monoblock Design.
- With thermal disconnect mechanical inside for fault indication by red indicator flag. Visual Indication: Green=OK, Red=Defect
- Floating changeover contact for monitoring device for options
- Voltage protection level (DC+) – PE, (DC-) – PE Up: <3,75 kV
- Voltage protection level (DC+) – (DC-) Up: <7,25 kV
- IP20 Degree of Ingress Protection
- Standards: EN 50539-11:2013 Low-voltage surge protective devices – Surge protective devices for specific application including d.c. – Part 11: Requirements and tests for SPDs in photovoltaic applications
- Standards: IEC 61643-31:2018 Low-voltage surge protective devices – Part 31 Requirements and test methods for SPDs for photovoltaic installations
- 1000Vdc, 1500Vdc approved by TUV, CB, CE
- Make the SPD with true RoHS material.
- 5 years warranty
T1+T2 PV Surge Protective Device FLPxxxG series are suitable for photovoltaic applications. These SPDs are designed and tested according to PV T1+T2 classification from IEC 61643-31 & EN 50539-11 standard.
FLP-PVxxxG-(S) | 1000 | 1500 |
IEC Electrical | ||
Maximum Continuous Operating DC Voltage (DC+) – PE, (DC-) – PE Ucpv (DC+) – (DC-) Ucpv | 725 V 1000 V | 1100 V 1500 V |
Nominal Discharge Current (8/20 μs) In | 20 kA | |
Impulse Discharge Current (10/350 μs) Iimp | 6.25 kA | |
Specific energy [DC+ -> PE/DC- -> PE] W/R | 9.76 kJ/ohms | |
Total Discharge Current (10/350 μs) ITotal | 12.5 kA | |
Specific energy [DC+/DC- -> PE] I | 39.06 kJ/ohms | |
Total Discharge Current (8/20 μs) ITotal | 40 kA | |
Maximum Discharge Current (8/20 μs) Imax | 40 kA | |
Voltage Protection Level (DC+) – PE, (DC-) – PE Up (DC+) – (DC-) Up | 2500 V 4750 V | 3750 V 7250 V |
Response Time tA | < 25 ns | |
Short-Circuit Current Rating ISCPV | 2000 A | |
Number of Ports | 1 |
Mechanical & Environmental | |
Operating Temperature Range Ta | -40 ºF to +158 ºF [-40 ºC to +70 ºC] |
Permissible Operating Humidity RH | 5%…95% |
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500 m … 2000 m |
Terminal Screw Torque Mmax | 39.9 Ibf·in [4.5 Nm] |
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) 35 mm2 (Solid, Stranded) / 25 mm2 (Flexible) |
Mounting | 35 mm DIN Rail, EN 60715 |
Degree Of Protection | IP 20 (built-in) |
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 |
Thermal Protection | Yes |
Operating State / Fault Indication | Green ok / Red defect |
Remote Contacts (RC) | Optional |
RC Switching Capacity | AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
RC Conductor Cross Section (max) | 16 AWG (Solid) / 1.5 mm2 (Solid) |
Order Information | ||
Order Code | 1000 | 1500 |
FLP-PVxxxG | 0710237 | 0715233 |
FLP-PVxxxG-(S) (with remote contacts) | 0710238 | 0715234 |
FAQ
Q1: Selection of surge protector
Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC 61643-31 & EN 50539-11 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of IEC 61643-31 & EN 50539-11 is Itotal (10/350) 12.5 ka, and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.
Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?
A2: We are a lightning surge protectors manufacturer.
Q3: Warranty and services:
A3:1. Warranty 5 years
2. lightning surge protectors products and accessories have been tested 3 times before ship out.
3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.
Q4: How can I get some lightning surge protectors samples?
A4: We are honored to offer you lightning surge protectors samples, pis contact our staff and leave detailed contact information, we promise to keep your information confidential.
Q5: Is the sample available and free?
AS: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.
Q6: Do you accept customized order?
A6: Yes, we do.
Q7: What’s the delivery time?
A7: It usually takes 7-15days after confirming payment, but the specific time should be based on the order quantity.
Packaging & Shipping